型号风量
(m3/h)
余压
(Pa)
冷量KW热量KW功率KW噪音db(A)重量Kg
回风工况新风工况回风工况新风工况
BFP-12WD12001806.713.511.416.80.255480
BFP-12XWD1508.317.815.419.685
BFP-15WD15001808.416.914.3210.325598
BFP-15XWD15010.422.319.324.5109
BFP-20WD200020011.222.519.1280.3756115
BFP-20XWD16013.929.725.732.7126
BFP-25WD250022001428.223.8350.4557129
BFP-25XWD18017.337.132.140.8142
BFP-30WD300023016.833.828.6420.5558149
BFP-30XWD19020.844.538.549161
BFP-35WD350020019.639.433.4490.7558154
BFP-35XWD16024.351.944.957.2169
BFP-40WD400020022.445.138.1560.37*258166
BFP-40XWD16027.759.351.365.3185
BFP-45WD450022025.250.742.9630.45*259175
BFP-45XWD18031.266.857.873.5191
BFP-50WD50002202856.347.7700.45*259183
BFP-50XWD18034.774.264.281.7198
BFP-60WD600023033.667.657.2840.55*260196
BFP-60XWD19041.6897798218
BFP-70WD700028039.278.966.7980.75*261208
BFP-70XWD24048.5103.889.8114.3242
BFP-80WD800030044.890.176.31120.75*261232
BFP-80XWD26055.5118.7102.7130.7265
BFP-90WD900036050.4191.485.81260.75*262246
BFP-90XWD30062.4133.5115.5147272
BFP-100WD1000040056112.795.31401.1*263268
BFP-100XWD36069.3148.3128.3163.3282
BFP-120WD1200045067.2135.2114.41681.5*264289
BFP-120XWD40083.2178154196325
BFP-150WD15000450841691432101.8*266321
BFP-150XWD400104222.5192.5245365
备注
   1.表中数据为《组合式空调机组》GB/T14294-2008国家标准规定的工况下测定值
     制冷工况:室内干球温度27℃,湿球温度19.5℃,进出水温度7/12℃
     制热工况:室内干球温度15℃,进水温度60℃,出水温度50℃
   2.表冷器、加热器排数要根据客户的实际工况选型
   3.空调机组的尺寸可根据客户要求定制